> Infant Care

Bilipod LED Phototheraphy Unit

Uniform Light Distribution: with 11 High Intensity LED Lamps High Irradiance Levels: allows faster Bilirubin breakdown Irradiance: > 40uW/cm2/nm at 35cm Light Weight: Lamp unit weighs no more than 3Kg Portable: Easily removable to be placed above incubator or below the Warmer Baby tray to give under surface Phototherapy Compact: Takes minimum space Lamp Unit Size: 24cm x 39cm x 8cm Lamp tilt: Up to 90° Height Adjustability: up to 50cm Observation Lamp: Two observation White LED's provide enough light to observe the color of baby's skin. Zero Noise Cooling Fan Very Low Power Consumption: of only 30W Life of Lamps: 30 000 hours Effective Surface area: 40cm x 50cm LCD Based Timer: measuring Total Lamp. Usage and Patient Timer Optional: Intensity Control:Control the intensity of the Phototherapy Unit with knob Optional: Irradiance Measurement: Inbuilt Irradiance sensor for measuring flux in uW/cm2/nm Category: Maternal and Infant Care

BiliPAD LED Phototherapy Blanket

BLANKET, PHOTOTHERAPY. SUITABLE FOR THE TREATMENT OF NEONATAL HYPERBILIRUBINEMIA LED PHOTOTHERAPY LIGHT SYSTEM, MICROPROCESSOR CONTROL LCD DISPLAY: TREATMENT TIME, / LAMP USAGE TIME SUITABLE FOR BABIES IN A BASSINET INCUBATOR, OPEN INCUBATOR OR RADIANT WARMER. NO LIGHT EMMISIONS IN THE ULTRAVIOLET OR INFRARED RADIATION SPECTRUM FLEXIBLE, DESIGN CONFORMING TO SHAPE OF NEONATE. PHOTOTHERAPY VIA LED LIGHT SOURCE TIME RECORDER OPERATIONAL WHEN PHOTOTHERAPY LIGHT SWITCHED ON. LED ARRAY REPLACEMENT SIMPLE, SECTIONAL REPLACEMENT OF LED ARRAY POSSIBLE, EFFECTIVE PHOTOTHERAPY TREATMENT. ISO 13458:2002 . ISO 9001:2008 . No. EC.1282.2P150116.AH0D51 .

Bilirubin Metre Probe

BILIRUBIN METER, NON-INVASIVE TRANSCUTANEOUS ASSESS THE RISK OF NEONATAL HYPERBILIRUBINEMIA. EFFECTIVE REGARDLESS OF SKIN COLOUR. SUITABLE FOR NEONATES OF GESTATIONAL AGE > 24 WEEKS. SUITABLE FOR NEONATES OF POSTNATAL AGE 0 - 20 DAYS. HANDHELD. EASY TO OPERATE. MEASUREMENT BY PLACING THE UNIT ON THE SKIN OF THE NEWBORN AND PRESSING IT LIGHTLY. THE MEASURING METHOD BASED ON THE DETERMINATION OF THE YELLOWNESS OF THE SUBCUTANEOUS TISSUE USING TWO OPTICAL PATHS TO MEASURE OPTICAL DENSITY DIFFERENCE AT TWO WAVELENGTHS. LIGHT SOURCE: XENON. NOT SENSITIVE TO USER-APPLIED PRESSURE OR ANGLE OF DEVICE. ABLE TO DISPLAY RESULT OF A SINGLE MEASUREMENT OR THE AVERAGE OF A NUMBER OF MEASUREMENTS. NOT SENSITIVE TO MOTION ARTIFACTS (OR MOVEMENTS) OF THE BABY. CAN BE USED WITH OR WITHOUT CONSUMABLE TIPS. DOES NOT REQUIRE ROUTINE CALIBRATION.

Neo-Tee Resuscitator

RESUSCITATOR, INFANT, GAS POWERED, PROVIDEs 100% OXYGEN FOR INFANTS UP TO 10 KG

Shelly Neo Natal Incubator

Incubator SHELLY provides a protected and comfortable environment and enables the healthcare staff to be always one step ahead of the demanding needs of the smallest patients. Acoustic comfort A quiet environment is the basic feature of infant incubators, but incubator SHELLY has brought it to perfection – the noise level in the patient space is only 38 dB. Thermal comfort An air curtain is automatically activated when the incubator door is opened, which reduces heat loss. Protection can be enhanced by a “click-in” double walled cover, which creates a more stable environment and provides an extra acoustic barrier. Sophisticated alarm announcement system As we care about the safety of small patients we have developed a sophisticated alarm announcement system. Two-stage light and acoustic signalling system exactly reflects the patient’s condition: PRODUCT DESCRIPTION Incubator SHELLY provides a protected and comfortable environment and enables the healthcare staff to be always one step ahead of the demanding needs of the smallest patients. ACOUSTIC COMFORT A quiet environment is the basic feature of infant incubators, but incubator SHELLY has brought it to perfection – the noise level in the patient space is only 38 dB. THERMAL COMFORT An air curtain is automatically activated when the incubator door is opened, which reduces heat loss. Protection can be enhanced by a “click-in” double walled cover, which creates a more stable environment and provides an extra acoustic barrier. SOPHISTICATED ALARM ANNOUNCEMENT SYSTEM As we care about the safety of small patients we have developed a sophisticated alarm announcement system. Two-stage light and acoustic signalling system exactly reflects the patient’s condition: Stage 1: caution, stage 2: warning The cause of the incubator alarm and advice how to solve it appears on the screen, and thus allows the doctor or the nurse to solve potential problems effectively.Dual control To provide even greater safety there is dual microprocessor control of all functions – everything is checked twice, by two independent processors. VITAL SIGNS MONITORING The precise and permanent monitoring of vital functions SpO2 including pulse, NIBP and RR is a reliable mechanism for providing complex and prudent medical care. The integrated monitoring system with adjustable alarm limits continuously records the measured values. CLEANING AND DISINFECTION The unique system of incubator SHELLY was designed not only for easy operation but also for effective cleaning. Smooth and simple design of the incubator with only a few detachable parts which are easy to disassemble and clean minimizes the time of entire procedure.