Description
PR4-g
Lung Ventilator for Transport and Emergency
The portable Lung Ventilator PR4-G was developed with advanced technology for use in intra and
extra hospital transportations, aeromedical rescue or emergency rooms, caring for adult, pediatric
and neonatal patients.
With volumetric and pressumetric controls, it presents in real time, through its LCD graphic
display, the visualization of all reading parameters, digital manometer and graphic of pressure by
time. It has adjustments of controls and alarms in its panel, of easy operation, facilitating the
control of the parameters to the operator
VENTILATION MODES
ADULT / PEDIATRIC
VCV assisted / controlled
PSV/CPAP
SIMV(VCV) + PSV
SIMV(PCV) + PSV
NEONATAL
PCV assisted / controlled
AUTOPEEP
With the AutoPEEP Ventilatory Mechanic, PR4-G evaluates the persistence of positive alveolar pressure at the end of the expiration, due to a final expiratory pulmonary volume higher than the foreseen functional residual capacity. The Auto P E E P occurs as consequence of the exhalation time being insufficient for the complete exhalation of the
patient.
INTERFACE AND VENTILATION MODES
With an LCD display of 7”, PR4-G holds a friendly and intuitive graphical interface, which allows the visualizaton of the ventilatory parameters and the curve of pressure by time. It is also composed of a large range of assisted
and controlled ventilatory modes capable of serving all patients, in an agile and easy to understand way.
NEONATAL MODE
The PR4-G is one of the most versatile transport ventilators in the market and may ventilate all patients, including newborns from 300g. With ventilatory modes such as continuous flow and nasal CPAP, and safety tools specific for the little ones, the PR4-G guarantees a proper ventilation for Neonatal
APPLICATIONS
PR4-g is a portable microprocessed lung ventilator which attends adult, pediatric and neonatal patients. The device is proper for versatile uses in intra and extra hospital mobile units, aeromedical rescue or emergency care.
SPECIAL CHARACTERISTICS
- Current time and date
- Safety for parameters configuration
- Symbol for silenced alarm
- Graphical indicator of external power supply and battery
- Indicator of the battery charge level
- Indicator of FiO in 50% or 100%.
- Symbol for Standby
- Symbol for alarms log
ADDITIONAL FUNCTIONS
- Indication menu of hours of use and services performed
- Possibility to change the language
- Initial self-tests
- Automatic altitude compensation
- Capture of atmospheric pressure
- Verification of the hours of use
- Calibration of the sensors
- Warning of the need of servicing per hours of use
- Battery charge indicator
PROGRAMMABLE ALARMS
- Maximum pressure
- Minimum pressure
- Maximum tidal volume
- Minimum tidal volume
- Maximum frequency
- PEEP
AUTOMATIC ALARMS
- Power failure
- Interrupted Cycle
- O failure
- Low battery charge
- Microprocessor (inoperative ventilator)
- Inverted I:E Ratio
- Patient disconnection
GRAPHICS
- Pressure – time
- Log of alarms or events with date, time and alarm
- Automatic scale for amplitude
MONITORING
Airway pressure: peak | 0 to 120 cmH2O |
Airway pressure: plateau | 0 to 120 cmH2O |
Airway pressure: base (PEEP) | 0 to 50 cmH2O |
Inspiratory time | 0 to 30s |
I:E Ratio and spontaneous breathings | 49:1 to 1:99 |
Inspiratory pause | 0 to 2s |
Total frequency | 250 rpm |
Graphical indicator of spontaneous and mechanical cycles | Symbols and graphics |
Indirect minute volum | 0 to 25 l/min |
FiO2 concentration | 50 or 100% |
Battery charge level | Proportional bar |
Indicator of battery or external power supply | Symbol |
LUNG MECHANICS
- AutoPEEP
- Inspiratory pause
CONTROLS
FiO2 | 50 or 100% |
Inspiratory Time | 0.1 to 30s + 2s of inspiratory pause |
I:E Ratio | 5:1 – 1:99 |
Ventilator Frequency | 1 – 150 rpm |
Tidal Volume | 5,0 to 2.500 ml |
Minute Volume (Indirectly Controlled) | 0.05 to 25.0 l (frequency x tidal volume) |
Sensibility | By pressure: -0.5 to -10.0 cmH2O (compensated PEEP) |
Pressure support (PSV) | 0 to 80 cmH2 O over PEEP |
Inspiratory pressure | -10 to 120 cmH2 O |
Rise time | 6 automatic levels |
Expiratory sensibility | 25% |
Apnea time | 5 to 60s |
PEEP / CPAP | 0 to 50 cm H2 O |
Inspiratory Flow | 0 to 120 l/min |
Base Flow | Off up to 50 l/min |
Automatic Inspiratory Pause (VCV mode) | 0.1 – 2.0s with plateau pressure value |
Flow waveform | Square |
Inspiratory pressure internal safety valve | Adjusted in 120 cmH2O |
O2 input pressure regulating valve | Internally incorporated into the equipment |
Graphics freeze | With grids for easy interpretation of the values |
Standby | Keeps the ventilator in standby without changing the programation |
Backup ventilation | Available in all ventilatory modes |
Altitude compensation | Automatic altitude compensation |
EXTERNAL CONVERTER (ADAPTER DC/DC, OPTIONAL)
Output voltage | 15 V |
Maximum output current | 2,33 A |
Power | 35,0 W (Max.) |
Input power | 9-36 V |
PNEUMATIC INPUT
Oxygen (O2) | DISS 9/16” – 18 input |
Pressure | 250 – 700 kPa (2,5 – 7 bar) |
Maximum consumption flow | Up to 160 l/min |
EXTERNAL POWER SUPPLY (AC/DC ADAPTER, OPTIONAL)
Voltage – Current | 100V – 240 V ~ 0,6 A – 0,29 A |
Rated power | 63 VA |
Power factor | 0,7 |
Output voltage | 15 V |
Maximum output current | 4,2 A |
PHYSICAL CHARACTERISTICS
Height | 150 mm |
Width | 270 mm |
Depth | 230 mm |
Equipment’s weight | 4.9kg |
Screen | 7 inches |
INTERNAL POWER SUPPLY
Rated power | 12 V |
Rated capacity | 13,2 Ah |
Type | Lithium (Li+) Battery |
Battery | 900 min. autonomy |
POWER SUPPLY
Voltage | 15 V (-20%) |
Rated current | 2,33 A |
Rated power | 35,0 W (Max.) |
Fuse | 3,0 A / 250 V 20 mm SB (retarded) |
Additional information
PR4-g Lung Ventilator | PR4-g Lung Ventilator |
---|