art. 501018
diameter: 5 mm
angle of view: 0°
working lengh: 301 mm
Laparoscope is designed for the optical observation of the surgical field for diagnostic examinations and surgical operations on internal organs. The diameter of the tube 5 mm. Working length 301 mm. The angle of viewing direction 0?. The optical system rod with multi-coated. Illuminated connector is 80? angle to the axis of the endoscope, for preventing unnecessary light guide cable bend at the junction and premature wear. Optics is compatible with all standard medical cameras. Can be used with high-definition cameras («HD and Full HD»). Housing material tube optical special corrosion-resistant steel. Material eyepiece medical plastic. It comes with two adapter cables to connect the light sources of various manufacturers (STORZ, R Wolf).
Additional information
Laparoscope TO1-050-300-00 Eleps | Laparoscope TO1-050-300-00 Eleps |
---|
Quick Comparison
Settings | Laparoscope TO1-050-300-00 Eleps remove | Spectrum remove | Incontinence Therapy Device Biolito remove | es 120 remove | ZEUS-200S /ZEUS-150 remove | Myolito Neuromuscular Stimulator remove | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Laparoscope TO1-050-300-00 Eleps remove | Spectrum remove | Incontinence Therapy Device Biolito remove | es 120 remove | ZEUS-200S /ZEUS-150 remove | Myolito Neuromuscular Stimulator remove | ||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||
SKU | ||||||||||||||||||
Rating | ||||||||||||||||||
Price | R5.00 | R5.00 | R5.00 | R5.00 | R5.00 | |||||||||||||
Stock | Out of stock | |||||||||||||||||
Availability | Out of stock | |||||||||||||||||
Add to cart | ||||||||||||||||||
Description | small surgical procedures for outpatient clinicsMonopolar work Bipolar work Automatic power regulation (Spectrum Result) SDS System NEM System Overload Protection Footswitch recognition Available also in 3-pin monopolar /2-pin bipolar version | 200W and 150W Electrosurgical Unit Recommendation of usage : Endoscopy surgery | ||||||||||||||||
Content | art. 501018
diameter: 5 mm
angle of view: 0°
working lengh: 301 mm
Laparoscope is designed for the optical observation of the surgical field for diagnostic examinations and surgical operations on internal organs. The diameter of the tube 5 mm. Working length 301 mm. The angle of viewing direction 0?. The optical system rod with multi-coated. Illuminated connector is 80? angle to the axis of the endoscope, for preventing unnecessary light guide cable bend at the junction and premature wear. Optics is compatible with all standard medical cameras. Can be used with high-definition cameras («HD and Full HD»). Housing material tube optical special corrosion-resistant steel. Material eyepiece medical plastic. It comes with two adapter cables to connect the light sources of various manufacturers (STORZ, R Wolf).
| SpectrumSmart Device System
Operating modes
Safety
comfort
Power output
| The Biolito is an inexpensive digital stimulator for incontinence therapy with an additional pain program according to Prof. Han. A program can - divided into up to 5 phases - be designed according to your own wishes.
Incontinence therapy includes forms of treatment for both stress and urge incontinence as well as fecal incontinence. Mixed incontinence can be comfortably treated with individually designed phases in a freely configurable program.
The therapy control of all important data is possible at a glance and the integrated real-time clock also allows the detailed evaluation of every session of the last 60 days of treatment.
Technical Specifications
Device Consists of:
| FeaturesSDS systemThe SmartDevice System detects and identifies the connected instrument. It automatically adjusts the operating mode and output settings to the instrument, thus improving the operator’s working comfort. The user does not have to wonder which mode and which setting to use for a specific instrument. The SmartDevice System identifies the instrument connected to spectrum. It automatically selects the modes in which it can be used and sets the suggested operating parameters for the identified instrument. In this way, it increases instrument life and safety of work.Spectrum ResultThe idea of spectrum is to set all parameters by default, and once selected, the settings will not require subsequent adjustments. SpectrumResult performs real-time monitoring of all operating parameters of the system: actual power, current intensity and voltage. Constant monitoring of all parameters always ensures the best result. With the solution used in SpectrumResult, the user does not need to control power settings. The electrosurgical system itself ensures that the output settings are maintained so as to obtain the desired effect of work, regardless of the surgical conditions.Touch screenEMED electrosurgical system are controlled with a touch screen which is designed to provide the user with easy access to all diathermy functions. The settings or modes of operation are changed by touching icons on the screen. To ensure maximum ease of operation there are no extra buttons or knobs.Program storage positionMemory program that allows customise settings for different interventions and surgeons.Bipolar cutting in liquidsThis operating mode is used for special bipolar forceps with two cutting loops that work in a physiological salt environment.MultiSwitchMultifunction footswitch allows remote changing of the settings with a single press of a footswitch.SurgilogicAutomatic regulation of the power supply level according to needs. A microprocessor monitors the tissue parameters on an ongoing basis to achieve the optimum cutting effect.NEM SystemThe NEM (Neutral Electrode Monitor) system controls the quality of the contact of a return electrode with the patient's skin. Using the NEM system, as well as two-compartment adhesive electrodes, it has totally eliminated the problem of burns to the patient's skin while applying a patient return electrode.AutoTestOnce switched on, EMED systems perform a comprehensive internal test, of which the result is displayed in the form of a precise, legible message.Overload ProtectionSupervising the temperature of the most critical components of the system makes it possible to avoid damaging the system, even if it is being heavily used.PowerStartIn situations of increased demand, the intelligent control system can temporarily increase the power supply to support the starting of the cutting process.Endoscopic program PPSpecial cutting modes necessary to remove polyps and the procedure of papillotomy. Alternating cutting and coagulation means optimal coagulation can be achieved for this application and reduces the probability of bleeding.Operating modes
Safety
Comfort
Power output
| The Myolito combines three forms of therapy in one device:
Four different operating modes can be used for pain therapy:
1. Continuous Tens (CONT):Unchanged flowing current impulses block the pain-conducting nerve tracts and create a permanent tingling sensation on the skin. With this classic type of treatment, the body can get used to the stimulus relatively quickly and the effect therefore diminishes with longer treatment.2. Dense-Disperse-Stimulation (CONT + BURST) according to Professor Han:The constant change between 2 Hz and 100 Hz in a short rhythm (2-4 seconds) ensures the release of different opioids with a lasting pain-relieving effect.3. Modulated Tens (MOD):Regular automatic changes of the parameters (frequency, pulse width and / or intensity) create the feeling of an increasing and decreasing current. This wave-like flow of current significantly delays the body's getting used to the stimulus.4. Burst (BURST):Twice a second, 9 impulses with a fixed frequency and pulse width are administered. This artificially generated frequency of 2 Hz is intended to increase the body's own endorphin production and thus combat pain in a natural way.Device Set Consists of:
| |||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||